SH2188 Diffused Silicon/Absolute Pressure Transmitter


Brief description SH2188 transmitter is consisted of piezoresistive sensor and signal conversion

module, sensor core is monocrystalline wafer, when monocrystalline wafer is

pressed, its resistivity will change, and diffuse to four resistances on the wafer,

form bridge, under constant current condition output voltage signal which is in

direct relation to pressure signal, and signal conversion module will convert

sensor voltage signal to 4~20mA DC standard signal.

SH2188 Pressure transmitter measures pressure and liquid level of fluid (liquid,

gas, vapor), and converts measured signal to 4~20mA DC standard signal. This

signal can be input signal of indication, record and regulator.

SH2188 is small size, light weight, high accuracy and low price, can be matched with field-indication meter, with zero displacement and range expansion functions, etc. Explosion-proof and intrinsic safety are optional, meet up with industrial requirements.

 

Parameters Main technical index

Application: liquid, gas and vapor

Range:2:0-0.02MPa ~ 0.1MPa

3:0-0.1MPa ~ 0.5MPa

4:0-0.2MPa ~ 1MPa

5:0-1MPa ~ 5MPa

6:0-2MPa ~ 10MPa

7:0-10MPa ~ 50MPa

Output:4 ~ 20mA DC

Power supply:12 ~ 36V DC

Output indication accuracy:±2%

Displacement: transmitter can be zero positive displacement of 50% calibration range, but calibration range upper limit should not be over max upper limit, can not be negative displacement.

Over pressure: twice of range limit (for range 0-50MPa, it's 1.5 times of range limit)

Working temperature:-25℃ ~ +80℃

Storage temperature:-40℃ ~ -120℃

Humidity:0 ~ 100% relative humidity

Start time:2 seconds no need of preheating

Accuracy:±0.20% of range, including linearity, difference, repeatability

Temperature influence: zero temperature error is 0.75%/55℃ of max range

Comprehensive temperature error is 1.1%/55℃of max range

Vibration influence:at any direction, vibration error is 0.25%/g of max range when vibration

fluency is 200HZ

Time response:less than 0.2s

Isolated diaphragm:316SST

Sensor body:1Cr18Ni9Ti

Filling oil:silicon oil

Flow connector:optional

Electric connection:Electronic box connection wiring hole is 1/2-14NPT taper tube thread hole, electric connection terminal strip is at side of Electronic box connection end. Weight: about 1kg.