The controller uses bellows-type sensor
which can be used in air, gas, vapor neutral gas
and water, oil and so on. the setting value is
adjustable and the range is 0.02-1.6 Mpa,
working pressure range is 0.05-2.5 Mpa.
|
|
Ordinary type |
Explosion-proof type |
|
Working Viscosity |
<1×10-3m2/s |
<1×10-3m2/s |
|
Switch Components |
Micro switch |
Micro switch |
|
Explosion –proof levels |
― |
ExdeⅡC Certificate numberGYB00108X |
|
Enclosure protection class |
IP65 |
IP54 |
|
Ambient temperature |
-30~50℃ |
-20~40℃ |
|
Media temperature |
0~120℃ |
0~95℃ |
|
Installation location |
|
Interface vertical downward |
|
Vibration resistance |
D520/7D:40 m/ s2
D520/7DK:20 m/ s2 |
Max:20m/s2 |
|
Repeatability error |
≤1% |
≤1% |
|
Contact capacity |
AC 220V 6A(Resistive) |
DC 250V 0.25A(Resistive)60Wmax
AC 250V 5A(Resistive)1250VAmax |