My status
Manufacturer
Product search
May  4 , 2024  Saturday
Home> level meter >> electrode type level meter >> UDK-900electric contact liquid level controller
  • Product number:MC-000443006834
  • Product name:electric contact liquid level controller
  • Product Type:UDK-900
  • Product nameplate:SAIC
  • Project Category:level meter >> electrode type level meter >>
  • Manufacturer:Shanghai Automation Instrumentation Co., Ltd.
  • Sales unit: Shanghai Automation Instrumentation Marketing Center
  • Information download:Click to enter the download page  
  • Introduction
  • Specifications
UDK-900 Series electric contact liquid level controller is a single-point level controller, liquid level can be used for conductive or conductive liquid and insulating liquid interface between the measurement control.
UDK-900 series break through the previous conductivity viscous liquid level controller can not be used in conductive media limitations, instrument electrodes are not afraid of contamination, has strong ability of anti-medium viscosity, instrument is sensitive to automatic adjustment, no adjustment is
can adapt to different conductivity of conductive medium. Moreover, the instrument measuring electrode used in all stainless steel and PTFE plastic composition, meet food hygiene requirements.
UDK-900 Series can not be used for insulating liquid level detection, when the liquid material containing soluble oil should be very careful, because the instrument may be insulated probe surface adhesion of oil closed up and can not correctly detect the tested liquid.
Model Specifications: UDK-900 Standard
UDK-902 XL (extended size 200; 500; 800; 1200; 1600; 2000mm 6 files)
Medium temperature: UDK-900 -30 ~ +100

UDK-902 -30 ~ +150

Medium pressure: 1.6MPa
Minimal medium conductivity: 30μs / cm
Ambient temperature: -25 ~ +55

Power: 220VAC 50Hz
Output signal: relay output, DPDT
Contact capacity: 200VAC, 0.5A
Alarm options: A: full-scale (upper limit) alarm, alarm status and relay alarm light goes out.
B: porosity (lower limit) alarm, alarm status relay release, warning lights.
Installation Type: screw installation, M36 × 2
Outlet thread :2-M16 × 1.5
,