medium: |
Liquid, gas, vapor |
Measure range: |
Reynolds 5X10^3~7X10^6 |
Working range: |
Reynolds 2X10^4~7X10^6(nominal path 25A~1OOA) |
4X10^4~7X10^6(nominal path 150A、 200A) |
liquid |
±1.0% of indicating value |
gas |
±1.0% of indicating value(flow speed is less than 35m/s) |
|
±1.5% of indicating value(flow speed is 35~80m/s) |
Repeatability: |
±0.2%of indicating value |
Range setting range: |
|
liquid: |
0-1.1m/s~0-10m/s(nominal path 25A~1OOA) |
0-1.5m/s~0-10m/s(nominal path 150A、200A) | |
0-1.7m/s~0-10m/s(nominal path 250A) | |
Gas or vapor: |
0-11m/s~0-80m/s (nominal path 25A~1OOA) |
0-15m/s~0-80m/s (nominal path 150A、200A) | |
0-17m/s~0-80m/s (nominal path 250A) | |
Output signal: |
A)analog DC4~20mA, two-wire |
B)Pulse three-wire voltage pulse low electric level:0~2V | |
C)RS-486 protocol:MODBUS protocol(only for YF/TBS) |