1. Electromagnetic flow converter
Input signal:Flow signal;
Output signal:
Current output:4~20mADC
Load resistance:0~750Ω
Load Capacitance:≤0.22 µF
Load inductance:≤3.3mH
Distance between wire:≥15cm
Input impendence:≥10kΩ
Maximum communication distance:2km
Output speed:0.0001~1000PPs
installation:
interface:JIS G1/2(PF1/2) internal thread
Terminal connection:M4 Screw
Enclosure material:Aluminum
2. Measuring tube
diameters:15,25,40,50,80,100,150,200mm
lining:Alumina
explosion-proof:FM explosion-proof
power consumption:≤13W
Insulation resistance:500V DC,between power supply and ground terminal 100MΩ
500V DC,between power supply and output terminal 1OOMΩ
1OOVDC,between output terminal and ground terminal 20MΩ
Insulation strength:1500V AC
Working condition:
Ambient temperature:-20~50℃
Power supply:
AC:100~240V AC,47—63Hz(100~120V DC
DC:24V DC
voltage frequency:47~63Hz
Fluid conductivity:≥0.01 s/cm