FBLU vortex flowmeter |
repeatability |
0.2% of indicating value |
Pressure loss |
△P=1.2×ρv2
v -- m/s ρ-- ㎏/m3 △P — Pa |
Nominal diameter |
25~250mm |
Working pressure |
2.5MPa,4.0MPa,6.3~16MPa |
media |
Superheated steam, saturated steam, compressed air and general air, water and liquid. |
Measure range |
Reynolds number 5000~7000000 |
Working range |
Reynolds number 20000~7000000 |
accuracy |
1.0% |
Media temperature |
-40~250℃(ordinary type),100~400℃(high temperature type) |
Power supply |
+24VDC |
Output signal |
Three-wire pulse output signal high electric level≥4V low electric level 0~1V
Two-wire current signal 4~20mA
Three-wire current signal 0~10mA |
Ambient condition |
Temperature -40~80℃;RH ≤90%RH |
Explosion-proof |
iaII CT5 |