My status
Manufacturer
Product search
November  22 , 2024  Friday
Home> flow meter >> dual bellows differential pressure manometer >> CWD-280 Dual Bellows Differential Pressure Meter
  • Introduction
  • Specifications
CWC-280、CWD-280 is used to continuously indicate the instantaneous value of measured parameter such as flow, pressure and level.
scale:Dial diameter 150mm,angle 270o
accuracy grade:1.0grade
number
specification
unit
CWE-280、410、610、430、630
CWD-
CWC-
280、272、282、288、274、276、410、610、430、630、632
1
Nominal pressure
MPa
0.4
6.4 16 32 40
2
Pressure, differential pressure upper limit
kPa
1 1.6 2.5 4
4 6 10 16 25 40 60
100 160 250 400
3
Pressure upper limit
MPa
1 1.6 2.5 4 6×10^n
4
Open container Level upper limit
mm
100 160 250 400
600 1000 1600 2500 4000 6000
10000 16000 25000 40000
5
Pressured container Level upper limit
mm
 
±200
±220
±300
±320
±500
 
6
Flow upper limits
m3/h
Nm3/h
t/h
kg/h
1 1.2 1.6 2 2.5 3 4 5 6×10^n
7
Basic error limit
 No additional equipment
%
±1.5
±1
 with additional equipment
-----
±1.5
8
Damp time
 open
s
-----
<=7
<=5
 close
>=6
>=12
9
Power supply
610\630
v AC/HZ
220/50
220/50
 
-----
10
Gas resource
 274
MPa
----
0.14
11
Output
276
mV
----
0-10
274
kPa
----
25-100
12
Power consumption
272\288
W
----
3.6
276
----
3
610\630
12
12
612\632
----
13
Load resistance
276
Ω
----
15-30(output 0-10mA)
90-120(output 0-50mV)
,