My status
Manufacturer
Product search
April  17 , 2024  Wednesday
Home> flow meter >> accumulating and controlling instrument >> XSF-40A Indicated Flow Totalizer
  • Introduction
  • Specifications
XSF-40A indicated flow totalizer is used with flow sensor to realize the following functions:
Accumulate total amount of flow
Indicate instantaneous flow value
Output 0~10mA or 4~20mA standard DC signal
Output electric pulse signal
Output 10Hz~50kHz frequency signal
The instrument uses two decimal and 2 integers. In the circuit, it uses CMOS integrated components, integrated power supply, integrated operational amplifier which makes the instrument high accuracy, low power consumption and easy operation. It is widely used in petroleum, chemical, metallurgy, power station and other departments.
Input impedance:≥3KΩ 
Input signal 
Frequency:20~5000Hz 
amplitude: 0.8~10V 
Waveforms: sine wave or basic symmetric square wave
Totalizer capacity: 999999 
Counting speed
Long time using:<5 times/second 
Fastest speed:< 15 times/second    
Setting range: 01.00~99.99 
Totalizer Errors;±0.01%
Indicating accuracy:2.5 grades 
weight:8kg 
output signal: 0~10mA or 4~20mA standard DC signal
Output Accuracy:±0.5% 
Response time:≤1S 
Ripple coefficient:≤0.2% 
Working condition
Ambient temperature: -10~45℃ 
RH:≤85% 
Power supply:220(+10%/-15%),50±5%