Cumulative capacity: 11 digital display,maximum 99999999999
Basic error of the cumulative flow: ≤±0.2%
The basic error of amount quantitative control: ≤±0.1%
Instantaneous flow:5 digital display,maximum 19999
Basic error of the instantaneous flow: ≤±0.3%
Electrical pulse input signal
Frequency: 1Hz~5000Hz
Amplitude: 0.8V~24V
Waveforms: sine wave or rectangular wave
Current input signal: 4~20mA
Output signal:
Standard DC signal: 4~20mA or 1~5V
Current basic error: ≤±0.5%F.S
Response time: ≮3s
Contact output: 2 relay contacts (normally closed)
volume:AV220V,0.5A;DC 24V,1A
Working condition
Ambient temperature: 0~+40℃
RH: ≤85%
Power supply: 220V AC,50Hz 24V DC
Power consumption: <5W
weight: 1.5kg
,