medium:Liquid, gas and vapor
output signal: two-wire 4~20mA
power supply: minimum 9VDC,12.5VDC maximum 45VDC
display: 2 line、5 digits
Explosion-proof performance: Explosion-proof, waterproof sealed enclosure; intrinsically safe(in line with FM、CSA、NEPSI and KEMA)
Ambient temperature: -40~85℃
Process Temperature: -40~100 ℃(Silicone oil)-40~85℃(Fluorine oil)
-29~149℃(filled with silicon oil)
15~300℃ (filled with high-temperature silicon oil)
Digital temperature: -25~70℃
Damp adjusting:0-32s through digital communication or button adjustable
configuration:Digital communication or button adjust
range:Differential pressure 0-0.125KPa to 0-7MPa
Gauge pressure 0-0.125KPa to 0-42MPa
Absolute pressure 0-200KPa to 0-2.1MPa
accuracy: ±0.075 % of F.S
Stability: 0.1 %/1 year
0.25 %/3 year
Range ratio: 100:1