Input range |
0~100kPa…1MPa…10MPa…50MPa…70MPa |
Overload |
2 times |
media |
Gas or liquid which no corrosive to stainless steel |
Working type |
Absolute pressure, gauge pressure, negative pressure |
Working voltage |
24VDC(9~36V) |
Output signal |
4~20mA or 1~5V |
Integrated Precision |
0.5%F.S |
Non-linear |
±0.5%F.S(typical value) |
Repeatability |
±0.5%F.S(typical value) |
output |
Two-wire or three-wire |
Ambient temperature |
-40~85℃ |
Temperature compensation |
25~80℃ |
Temperature drift |
0.5%F.S/℃ |
Thread interface |
≤±0.5%F.S/year |
Electrical connection |
M12×1、74°cone M20×1.5 1/4NPT G1/4 |
Ambient temperature |
Cable Connection、 big Hirschmann |
3 1/2LED、LCD display |