Output current: 4~20mA DC
Load resistance:0~250Ω(Wiring resistance ≤100Ω)
Sensitivity limit:0.1%
Pressure error:±3%(≤6.4MPa) ±5%(≥32MPa)
Working condition:ambient temperature:-25~60℃ RH:≤95%
Working vibration:frequency ≤10~55Hz amplitude ≤0.15mm
Power supply:24V DC±5%
Power consumption:≤6W
structure:Field Installation
Connector thread:M18×1.5
Intrinsically Safety mark:ibⅡBT4
Explosion-proof mark:BXdI/ⅡBT4