Basic error:Instantaneous flow value, the accumulated value, temperature and pressure O.5%
range:pressure: 1~3.5MPa,temperature: 100℃~450℃
Detection rate:7 input signal/second
display:Digital display
output:Accumulated pulse signal and analog signal 4~20mA or O~20mA.
input:
1、flow signal: O~10mA,4~20mA from vortex flow meter or differential pressure transmitter,Pulse frequency O~5kHz from flow transmitter;
Low electric level: O~2V,
high electric level 8~24V。
2、pressure signal I2:O~10mA or 4~20mA from pressure transmitter
3、temperature signal: R11~R13 from Ptl00 platinum resistance
Input impendence: 200Ω
100Ω(4~20mA)
Working temperature:0~40℃
RH:5~90%
Power supply:AC 220V(+10%~15 %),50Hz±5%
Power consumption:<15VA
Case size:80×160×250mm (length × width × depth)
Hole Size:(152+1)× (76+1) mm (length × width)
weight:3kg