- Home
- |
- About us
- |
- Certificate
- |
- Products
- |
- Performance
- |
- Member
- |
- News
- |
- Technical Support
- |
- Contact us
It is a thermocouple without fixed device ,but with Ceram protective pipe.
Thermocouple category |
Model |
Graduation |
Temperature measuring range℃ |
Specification |
Thermal response time
τ0.5s | |
Diameter
mm |
Protection tube material | |||||
Single platinum rhodium30-platinum rhodium6 |
WRR-130B |
B |
0~1600 |
Φ16 |
Corundum |
<150
<360
<150
<360 |
WRR-131B |
Φ25 | |||||
Double platinum rhodium30-platinum rhodium6 |
WRR2-130B |
Φ16 | ||||
WRR2-131B |
Φ25 |
Thermocouple types |
Code
|
Graduation |
Temperature measuring range |
Allowable deviation△t℃ |
30%Platinum rhodium -6%platinum rhodium |
WRR |
B |
0-1800 |
±1.5oC or ±0.0025|t| |
10%Platinum rhodium -platinum |
WRP |
S |
0-1600 |
±1.5 oC or ±0.0025|t|
|
Nickel chrome-nickel silicon |
WRN |
K |
0-1300 |
±2.5 oC or ±0.0075|t|
|
Nickel chrome-copper nickel |
WRE |
E |
0-800 |
±2.5 oC or ±0.0075|t|
|