Accuracy :basic error is not more than ±1% of the measurement range
Environment temperature : 20±5%
Correct installation :
Less vibration
Pressure of input signal : 20~100kPa
Temperature error :when the environment temperature pass 20±5℃, Every change in 1 ℃ ,error changes not more than 0.04% of the measurement range
Air supply :clean and dry compressed air, supply pressure is 0.3~1MPa,when the pressure of input signal is 20~100kPa, air consumption is not more than 150L/h。
Weight :3.5 kg
Alarm accuracy and volume: alarm error is not more than ±1.5% of the working pressure .
Micro Switch Contact volume: AC<250 1A DC<30V 0.5A
Specifications and parameters
Model |
Instruction |
Notes |
QXZ-110 |
Show a parameter |
(1)Ribbon Color: red、green、blue。
(2)Indicate the color when ordering |
QXZ-111 |
Show a parameter, with upper alarm |
QXZ-112 |
Show a parameter, with lower alarm |
QXZ-113 |
Show a parameter, with upper and lower alarm |
, ,