Input signal: 0~10mA DC(Impedance : 800 or 1KΩ)  4~20mA DC(Impedance : 250Ω)
Pulse amplitude: ZK-1、ZK—0>3V(200Ω load)
               ZK-3、ZK-3A、ZK-3B  ZK-03、ZK—03A、ZK-03B>4V(200Ω load)
              ZK-3A、ZK-3B、ZK-03A、ZK—03B、 ZK-30(60o complement pulse per half week)
Pulse width: ZK-1、ZK-3>30itS
            ZK-0、ZK-3A、ZK-3B、ZK-03A、 ZK-30B>200μs
Maximum conduction angle >150o
Zero-crossing triggering cycle:ZK-0、ZK-03:5±2S  
                          ZK-03A、ZK-03B、ZK-30C  :7~10±2S
Supply voltage: 220V AC±10%
Working temperature: 0~50℃  ,relative humidity: ≤85%RH  ,vibration-free and non-corrosive gases occasions.
Model specification
| 
    functions  | 
      model specification  | 
  Terminal diagram No.  | 
| 
 single-phase phase-shift trigger  | 
 ZK-1、  ZK-1C  | 
 76-01~02  | 
| 
 single-phase  zero-crossing trigger  | 
 ZK-O、  ZK-0C  | 
 76-03~04  | 
| 
 three-phase phase-shift trigger  | 
 ZK-3、ZK-3A、ZK-3B  | 
 76-05 77-03~02  | 
| 
 three-phase phase-crossing trigger  | 
 ZK-03、ZK-03A、ZK-3B  | 
 77-01 77-05~04  | 
| 
 three-phase phase-crossing /phase-shift trigger  | 
 ZK-30A、  ZK-30B  ZK-30C  | 
 78—01  | 
Note:
ZK-3, ZK-03 is as a three-phase half-controlled, improved version is semi-control or full control
 “C”is the installation type of instruments一wall 
ZK-3A、ZK-3B、ZK-03A、ZK-03B are improved instruments and “A” is horizontal, “B” is straight.
Three-phase trigger ZK 3A(B)、ZK-03A(B)、ZK-30A(B)、ZK-30C Extensible functionality:Soft start, over-current protection, soft start and overcurrent protection, inductive loads such as zero-crossing triggering.