Input signal: resistance thermometer signal or thermocouple signal; millivolt signal.
Output signal: 4~20mA DC
Allowable load resistance:0~550Ω
Explosion-proof type and classification: Ex(ia)ⅡC
range |
Basic error |
2mV≤input signal<3mV(3Ω≤ΔR<6Ω) |
±1.5% |
3mV≤input signal <5mV(6Ω≤ΔR<10Ω) |
±1.0% |
input signal≥5mV(ΔR≥10Ω) |
±0.5% |
Cool terminal temperature Compensation error::≤1.5℃
Power supply:24VDC±10%
consumption power:About 2W
Operating condition
Ambient temperature:5~40℃
Relating humility:5%~85%
Working vibration:frequency <55Hz,amplitude<0.075mm
external magnetic field:<400A/m