My status
Manufacturer
Product search
April  24 , 2024  Wednesday
Home> marine meter >> current、voltage、power transmission module >> HR-WP20 Voltage and current transmission module
  • Introduction
  • Specifications
Products description
It is a miniature cartridge converter.It convert the signal of  voltage(mV or V)、current(mA) into the proportional output signal of with the isolation of 1~5VDC or 4~20mADC.
It is an intelligent transmitter,calculating with microprocessor.
You can choose two kinds of powers(AC ,DC power),it has output signal (1~5VDC or 4~20mADC) selsct and disconnection protection.It can also switch between many indexing Numbers.(except for input signal of power).
Specifications and parameters
Input
mV:3~100mV
V:0~100VDC(absolute valut<100V)
mA:0~20mADC
frequency:Waveform - rectangular, sine or triangle wave
Range—>4V(or according to users’ requirements)
Power range—0~5KHz(or according to users’ requirements)
Input Resistance
>250KΩ( input:1~5V)
<250Ω(input:4~20mA)
Zero migration
Input -100%~+100% of the range
Source Resistance
<500Ω(value:<±0.1%/150Ω)
Output
Two isolated outputs
first:1~5VDC or 4~20mADC(uses can choose, 4~20mADC out of factory)
second:1~5VDC or 4~20mADC
 
Output resistance
<250Ω(output:1~5VDC)
Allowed load resistance
0~600Ω(output:4~20mADC)
accuracy
±0.5%FS or ±0.2%FS
Specifications setting
setted by HR-WP20SHA display module
Response time
mV input:about 500ms
V、mA input:about 100ms
isolation
input、output、isolation between powers
power
Supply AC or DC
AC:90~265V switching power ;AC220V linear power
DC:24V±10%
Power consumption
When 220VAC,≤3W
When 24VDC,≤100mA
Working temperature
0~55℃
Relative humidity
5~99%RH
Insulation resistance
Between terminals and earth terminals:100MΩ/500VDC
Insulation strength
Between terminals and earth terminals:1500V AC,1 minute
input/output terminals and earth terminals:500VDC,1 minute
structure
miniature cartridge
weight
main:about 180g; outlet:about 80g