Home> temperature meter >> temperature transmitter >> SBWZ-2470/24skd Explosion-proof and Intrinsically Safe Temperature Transmitter with Thermocouple/ Thermal resistor
  • Product number:MC-000016002377
  • Product name:Explosion-proof and Intrinsically Safe Temperature Transmitter with Thermocouple/ Thermal resistor
  • Product Type:SBWZ-2470/24skd
  • Product nameplate:SAIC
  • Project Category:temperature meter >> temperature transmitter >>
  • Manufacturer:Shanghai Automation Instrumentation Co., Ltd.
  • Sales unit: Shanghai Automation Instrumentation Marketing Center
  • Information download:Click to enter the download page  
  • Introduction
  • Specifications
SBW series explosion-proof and intrinsically safe temperature transmitter with Thermocouple/ Thermal resistor is an on-site installation temperature transmission unit of DDZ-S Series instrument. It combines transmitter with thermocouple (Thermal resistor) as one unit to measure temperature of liquid, vapor and within -200~800℃ in production. It will convert temperature into 4~20mADC unified output signal which has direct ratio with thermocouple temperature or output signal then send to display, record devices or computers. The explosion-proof performance of temperature transmitter is designed and manufactured according to "explosive environment, explosion-proof electrical equipment" (GB3836) which promulgated by our nation. Thermoelectric properties are in line with international IEC standards and tested by National Safety Supervision Station. It is the ideal transmission temperature sensor in explosive environment. The explosion-proof certification number is GYB 93265、93266、97336、97337.
As a new-type of temperature transmitter, it is widely used in metallurgy, petroleum, chemical, electric power, light industry, textiles, food, national defense and scientific research sectors.
Accuracy grade of Platinum thermal resistance:B grade
Indexing Number:Pt100. (resistance value at 0℃)
R=1000.12Ω(B grade)
Allowable bias:Δt(℃)±(0.30+0.005∣t∣)(B grade)
input:thermocouple:K,E
thermal resistor:Pt100
basic error:Formula Δ=Δ1+Δ2
Δ1 is allowable error of thermocouple (thermal resistor)
Δ2 is basic error±0.5%FS of transmitter
Transmission:Two-wire
Power supply:Minimum Voltage 12V,Maximum voltage 35V,rated voltage 24V。
Load resistance:RL(max)=50×(Vmin-12)( 24V load resistance can be used in 0~600Ω,rated load resistance is 250Ω。)
a. ambient temperature:-25℃~80℃(no more than 70℃ in dangerous place)。
b. RH:5%~95%。
C Mechanical Vibration:f≤55Hz,amplitude <0.5mm
d. without corrosive gas in ambient
Explosion-proof grade:
Explosion suppression:dⅡBT4  dⅡBT6   or dⅡCT4  dⅡCT6
Intrinsically Safe type:ibⅡBT4  iaⅡBT4  iaⅡCT6
Enclosure protection class:IP65
□model marks
S
DDZ-S series instrument
B
Transmitter unit
W
temperature
 
empty)general type
Z  thermal resistor
R thermocouple

output
2)output and corresponding temperature
 
4)linear relationship between output and input signal
 

sensor
0)general type

thermocouple
0)E Nickel-chromium - copper-nickel
1)K Ni-Cr - Ni-Si
2)S Platinum and rhodium 10-Platinum

thermal resistor
1)Cu50
2)Cu100
3)Pt100

circuit
7)Isolated type(With a temperature measurement device)
8)Non-Isolated(with a temperature measurement device)
 
 
element
0) general type
1) Intelligence type
2) Digital Display Type
3) Pointer type
4) Intelligent Digital Display Type
5) Intelligent pointer type
6) With a communication protocol
 

installation and fixed
2)Fixed thread
4)Fixed Flange
6)Fixed threaded cone shape protection tube
8) fixed internal thread
9)thermal protection tube

junction box
4)explosion suppression type

design series NO.
S)introduced platinum resistance
0) thermocouple
1) Insulation Type(armored)
2) case connection type(armored)

number of element
3)Three pairs type

Supplement
K)armored type

Environmental Characteristics
d) explosion suppression type
i) Intrinsically Safe type